I_FMEANode
Function or other node of FMEA
I_FMEANode is a Basic CDS View that provides data about "Function or other node of FMEA" in SAP S/4HANA. It reads from 1 data source (plmm_quest_res) and exposes 46 fields with key field FMEANodeUUID. It has 17 associations to related views. Part of development package PLM_FMEA.
Data Sources (1)
| Source | Alias | Join Type |
|---|---|---|
| plmm_quest_res | plmm_quest_res | from |
Associations (17)
| Cardinality | Target | Alias | Condition |
|---|---|---|---|
| [1..1] | I_FMEANodeAssignment | _FMEANodeAssignment | $projection.FMEANodeUUID = _FMEANodeAssignment.FMEANodeUUID |
| [0..1] | I_FailureModeEffectAnalysis | _FailureModeEffectAnalysis | $projection.FMEAHeaderUUID = _FailureModeEffectAnalysis.FMEAHeaderUUID |
| [1..1] | I_FMEAHeader | _FMEAHeader | $projection.FMEAHeaderUUID = _FMEAHeader.FMEAHeaderUUID |
| [0..1] | I_FMEANodeHierarchy | _FMEANodeHierarchy | $projection.FMEANodeUUID = _FMEANodeHierarchy.FMEANodeUUID |
| [0..*] | I_FMEANodeHierarchy | _FMEANodeChild | $projection.FMEANodeUUID = _FMEANodeChild.FMEAParentNodeUUID |
| [0..1] | I_FMEAValuationProfile | _FMEAValuationProfile | $projection.FMEAValuationProfile = _FMEAValuationProfile.FMEAValuationProfile |
| [0..1] | I_InspectionCodeGroup | _InspectionCodeGroup | $projection.InspectionCatalog = _InspectionCodeGroup.InspectionCatalog and $projection.InspectionCodeGroup = _InspectionCodeGroup.InspectionCodeGroup |
| [0..1] | I_InspectionCode | _InspectionCode | $projection.InspectionCatalog = _InspectionCode.InspectionCatalog and $projection.InspectionCodeGroup = _InspectionCode.InspectionCodeGroup and $projection.InspectionCode = _InspectionCode.InspectionCode |
| [0..*] | I_FMEATask | _FMEATask | $projection.FMEANodeUUID = _FMEATask.FMEAParentNodeUUID |
| [0..*] | I_FMEANodeText | _FMEANodeText | $projection.FMEANodeUUID = _FMEANodeText.FMEANodeUUID |
| [1..1] | I_FMEANodeAssignment | _FMEAReferenceAssignment | $projection.FMEANodeReferenceUUID = _FMEAReferenceAssignment.FMEANodeUUID |
| [0..1] | I_FMEANode | _FMEAReferenceNode | $projection.FMEANodeReferenceUUID = _FMEAReferenceNode.FMEANodeUUID |
| [1..1] | I_FMEAHeader | _FMEAReference | $projection.FMEANodeReferenceUUID = _FMEAReference.FMEAHeaderUUID |
| [0..1] | I_FMEAValuationProcedure | _FMEAValuationProcedure | $projection.FMEAValuationProcedure = _FMEAValuationProcedure.FMEAValuationProcedure |
| [0..*] | I_FMEALongText | _FMEANodeLongText | $projection.FMEANodeUUID = _FMEANodeLongText.FMEANodeUUID and _FMEANodeLongText.LongTextInternalNumber = 1 |
| [0..1] | I_FMEAText | _FMEAHeaderText | $projection.FMEAHeaderUUID = _FMEAHeaderText.FMEAHeaderUUID and _FMEAHeaderText.Language = $session.system_language |
| [1..1] | E_FMEANode | _Extension | $projection.FMEANodeUUID = _Extension.FMEANodeUUID |
Annotations (10)
| Name | Value | Level | Field |
|---|---|---|---|
| AbapCatalog.sqlViewName | IFMEANODE | view | |
| ClientHandling.algorithm | #SESSION_VARIABLE | view | |
| VDM.viewType | #BASIC | view | |
| AbapCatalog.compiler.compareFilter | true | view | |
| AccessControl.authorizationCheck | #CHECK | view | |
| EndUserText.label | Function or other node of FMEA | view | |
| ObjectModel.representativeKey | FMEANodeUUID | view | |
| ObjectModel.usageType.serviceQuality | #B | view | |
| ObjectModel.usageType.sizeCategory | #M | view | |
| ObjectModel.usageType.dataClass | #TRANSACTIONAL | view |
Fields (46)
| Key | Field | Source Table | Source Field | Description |
|---|---|---|---|---|
| KEY | FMEANodeUUID | |||
| FMEAHeaderUUID | ||||
| FMEAHierarchyProfile | plmm_quest_res | hierarchy_profil | Hierarchy Prof. | |
| FMEAHierarchyProfileLevel | plmm_quest_res | hierarchy_level | Hierarchy Level | |
| FMEANodeType | plmm_quest_res | node_type | Type | |
| FMEANodeListType | plmm_quest_res | listtyp | List Type | |
| FMEAItemType | plmm_quest_res | listityp | Item Type | |
| FMEANodeReferenceUUID | Value | |||
| FMEANodeReferenceObjectType | reference_obtyp | Object Type | ||
| FMEAValuationProfile | plmm_quest_res | assessm_profil | Valuatn Profile | |
| FMEAHasValuation | plmm_quest_res | assessment_rec | Val. Entered | |
| FMEAValnProfileValuation | plmm_quest_res | assessment_res | Valuation | |
| FMEAValuationScoreValue | plmm_quest_res | score_rec | Tgt No.Points | |
| FMEAValuationResultValue | plmm_quest_res | score_res | Target Result | |
| InspectionCatalog | plmm_quest_res | katalgart | Catalog Type | |
| InspectionCodeGroup | plmm_quest_res | gruppe | Code Group | |
| InspectionCode | plmm_quest_res | code | Water Hazard Cl. | |
| DefectCodeCatalog | plmm_quest_res | fekat | Defect types | |
| DefectCauseCodeCatalog | plmm_quest_res | urkat | Catalog type | |
| FMEAFunctionCodeCatalog | plmm_quest_res | functioncat | Funct. Catalog | |
| FMEAEffectCodeCatalog | plmm_quest_res | effectcat | Effects Catalog | |
| QualityTaskCodeCatalog | plmm_quest_res | makat | Catalog type | |
| InspectionSpecification | plmm_quest_res | verwmerkm | Master IC | |
| InspectionSpecificationPlant | plmm_quest_res | qpmk_werks | Plant | |
| InspSpecImportanceCode | plmm_quest_res | merkgew | Weighting | |
| FMEACharacteristicType | plmm_quest_res | char_type | Characteristic Type | |
| ChangedDateTime | plmm_quest_res | changeddatetime | Time Stamp | |
| FMEAValuationProcedure | plmm_quest_res | audit_calculate | Procedure | |
| FMEARating | plmm_quest_res | classification_code | Rating | |
| OriginalLanguage | plmm_quest_res | original_langu | Original Language | |
| _FailureModeEffectAnalysis | _FailureModeEffectAnalysis | |||
| _FMEAHeader | _FMEAHeader | |||
| _FMEANodeAssignment | _FMEANodeAssignment | |||
| _FMEANodeHierarchy | _FMEANodeHierarchy | |||
| _FMEANodeChild | _FMEANodeChild | |||
| _FMEATask | _FMEATask | |||
| _FMEAValuationProfile | _FMEAValuationProfile | |||
| _FMEANodeText | _FMEANodeText | |||
| _FMEAReferenceAssignment | _FMEAReferenceAssignment | |||
| _FMEAReferenceNode | _FMEAReferenceNode | |||
| _FMEAReference | _FMEAReference | |||
| _InspectionCodeGroup | _InspectionCodeGroup | |||
| _InspectionCode | _InspectionCode | |||
| _FMEAValuationProcedure | _FMEAValuationProcedure | |||
| _FMEANodeLongText | _FMEANodeLongText | |||
| _FMEAHeaderText | _FMEAHeaderText |
Derived SQL interpretation, reconstructed from the parsed view metadata (data sources, associations, and field mappings). SAP annotations are omitted and the structure is reformulated as SQL — this is a functional approximation, not the verbatim SAP source.
-- Derived SQL interpretation of CDS view I_FMEANode.
-- Reconstructed from parsed metadata (data sources, associations, fields).
-- SAP annotations are omitted and the structure is reformulated as SQL;
-- this is a functional approximation, not the verbatim SAP source. Some join
-- conditions may be unavailable and a few CDS constructs are kept as-is.
-- SQL view name: IFMEANODE
CREATE VIEW I_FMEANode AS
SELECT
cast( plmm_quest_res.guid as plmt_fmea_node_guid preserving type ) AS FMEANodeUUID,
cast( plmm_quest_res.project_guid as plmt_fmea_node_guid preserving type ) AS FMEAHeaderUUID,
plmm_quest_res.hierarchy_profil AS FMEAHierarchyProfile,
plmm_quest_res.hierarchy_level AS FMEAHierarchyProfileLevel,
plmm_quest_res.node_type AS FMEANodeType,
plmm_quest_res.listtyp AS FMEANodeListType,
plmm_quest_res.listityp AS FMEAItemType,
cast( reference as plmt_fmea_node_guid preserving type ) AS FMEANodeReferenceUUID,
reference_obtyp AS FMEANodeReferenceObjectType,
plmm_quest_res.assessm_profil AS FMEAValuationProfile,
plmm_quest_res.assessment_rec AS FMEAHasValuation,
plmm_quest_res.assessment_res AS FMEAValnProfileValuation,
plmm_quest_res.score_rec AS FMEAValuationScoreValue,
plmm_quest_res.score_res AS FMEAValuationResultValue,
plmm_quest_res.katalgart AS InspectionCatalog,
plmm_quest_res.gruppe AS InspectionCodeGroup,
plmm_quest_res.code AS InspectionCode,
plmm_quest_res.fekat AS DefectCodeCatalog,
plmm_quest_res.urkat AS DefectCauseCodeCatalog,
plmm_quest_res.functioncat AS FMEAFunctionCodeCatalog,
plmm_quest_res.effectcat AS FMEAEffectCodeCatalog,
plmm_quest_res.makat AS QualityTaskCodeCatalog,
plmm_quest_res.verwmerkm AS InspectionSpecification,
plmm_quest_res.qpmk_werks AS InspectionSpecificationPlant,
plmm_quest_res.merkgew AS InspSpecImportanceCode,
plmm_quest_res.char_type AS FMEACharacteristicType,
plmm_quest_res.changeddatetime AS ChangedDateTime,
plmm_quest_res.audit_calculate AS FMEAValuationProcedure,
plmm_quest_res.classification_code AS FMEARating,
plmm_quest_res.original_langu AS OriginalLanguage
FROM plmm_quest_res
LEFT OUTER JOIN I_FMEANodeAssignment AS _FMEANodeAssignment ON FMEANodeUUID = _FMEANodeAssignment.FMEANodeUUID -- association [1..1]
LEFT OUTER JOIN I_FailureModeEffectAnalysis AS _FailureModeEffectAnalysis ON FMEAHeaderUUID = _FailureModeEffectAnalysis.FMEAHeaderUUID -- association [0..1]
LEFT OUTER JOIN I_FMEAHeader AS _FMEAHeader ON FMEAHeaderUUID = _FMEAHeader.FMEAHeaderUUID -- association [1..1]
LEFT OUTER JOIN I_FMEANodeHierarchy AS _FMEANodeHierarchy ON FMEANodeUUID = _FMEANodeHierarchy.FMEANodeUUID -- association [0..1]
LEFT OUTER JOIN I_FMEANodeHierarchy AS _FMEANodeChild ON FMEANodeUUID = _FMEANodeChild.FMEAParentNodeUUID -- association [0..*]
LEFT OUTER JOIN I_FMEAValuationProfile AS _FMEAValuationProfile ON FMEAValuationProfile = _FMEAValuationProfile.FMEAValuationProfile -- association [0..1]
LEFT OUTER JOIN I_InspectionCodeGroup AS _InspectionCodeGroup ON InspectionCatalog = _InspectionCodeGroup.InspectionCatalog AND InspectionCodeGroup = _InspectionCodeGroup.InspectionCodeGroup -- association [0..1]
LEFT OUTER JOIN I_InspectionCode AS _InspectionCode ON InspectionCatalog = _InspectionCode.InspectionCatalog AND InspectionCodeGroup = _InspectionCode.InspectionCodeGroup AND InspectionCode = _InspectionCode.InspectionCode -- association [0..1]
LEFT OUTER JOIN I_FMEATask AS _FMEATask ON FMEANodeUUID = _FMEATask.FMEAParentNodeUUID -- association [0..*]
LEFT OUTER JOIN I_FMEANodeText AS _FMEANodeText ON FMEANodeUUID = _FMEANodeText.FMEANodeUUID -- association [0..*]
LEFT OUTER JOIN I_FMEANodeAssignment AS _FMEAReferenceAssignment ON FMEANodeReferenceUUID = _FMEAReferenceAssignment.FMEANodeUUID -- association [1..1]
LEFT OUTER JOIN I_FMEANode AS _FMEAReferenceNode ON FMEANodeReferenceUUID = _FMEAReferenceNode.FMEANodeUUID -- association [0..1]
LEFT OUTER JOIN I_FMEAHeader AS _FMEAReference ON FMEANodeReferenceUUID = _FMEAReference.FMEAHeaderUUID -- association [1..1]
LEFT OUTER JOIN I_FMEAValuationProcedure AS _FMEAValuationProcedure ON FMEAValuationProcedure = _FMEAValuationProcedure.FMEAValuationProcedure -- association [0..1]
LEFT OUTER JOIN I_FMEALongText AS _FMEANodeLongText ON FMEANodeUUID = _FMEANodeLongText.FMEANodeUUID AND _FMEANodeLongText.LongTextInternalNumber = 1 -- association [0..*]
LEFT OUTER JOIN I_FMEAText AS _FMEAHeaderText ON FMEAHeaderUUID = _FMEAHeaderText.FMEAHeaderUUID AND _FMEAHeaderText.Language = $session.system_language -- association [0..1]
LEFT OUTER JOIN E_FMEANode AS _Extension ON FMEANodeUUID = _Extension.FMEANodeUUID -- association [1..1]
;
Learn More
- VDM (Virtual Data Model) in SAP S/4HANA Explained
- Types of CDS Views: Basic, Composite, Consumption, and Transactional
- CDS View Annotations — A Complete Guide
- What Is a CDS View in SAP S/4HANA?
- SAP Tables vs CDS Views — Key Differences
- Understanding Data Lineage in SAP S/4HANA
- CDS View Field Mapping and Associations
- Understanding the SAP S/4HANA Data Model
- CDS View Extensions and Custom Fields in SAP S/4HANA
- Released APIs and Stability Contracts in SAP S/4HANA
- BSEG to ACDOCA: The Universal Journal Migration
- Business Partner Migration: KNA1/LFA1 to BUT000
- Material Document Migration: MSEG/MKPF to MATDOC
- How to Find the Right CDS View for an SAP Table
- BW Extractor to CDS View Migration Guide
- S/4HANA CDS View Deprecation: What You Need to Know
- ABAP CDS View Tutorial — From Basics to Real-World Examples
- RAP and CDS Views — Building Transactional Apps in SAP S/4HANA
- Sales Document Status Migration: VBUP/VBUK Removal in S/4HANA
- CO Tables in S/4HANA: COEP, COBK, COSS, COSP to ACDOCA