C_PCEctxStbltyWaterTP

DDL: C_PCECTXSTBLTYWATERTP Type: view CONSUMPTION

Stability in Water

C_PCEctxStbltyWaterTP is a Consumption CDS View that provides data about "Stability in Water" in SAP S/4HANA. It reads from 1 data source (I_PCEctxStbltyWaterTP) and exposes 16 fields. It has 4 associations to related views.

Data Sources (1)

SourceAliasJoin Type
I_PCEctxStbltyWaterTP I_PCEctxStbltyWaterTP from

Associations (4)

CardinalityTargetAliasCondition
[1..1] C_PCEctxPropertyTP _PCEctxProperty $projection.PCEctxPrptyUUID = _PCEctxProperty.PCEctxPrptyUUID -- Unit of Measure - Temperature
[0..*] I_UnitOfMeasureText _UnitOfMeasureTemperature $projection.PCEctxStbltyWaterTempQtyUoM = _UnitOfMeasureTemperature.UnitOfMeasure -- Unit of Measure - TypeValue
[0..*] I_UnitOfMeasureText _UnitOfMeasureHalfLifeValue $projection.PCEctxHalfLifeUoM = _UnitOfMeasureHalfLifeValue.UnitOfMeasure --Rating text
[0..*] I_ProdCmplncRatingText _ProdCmplncRatingText $projection.PCEctxRating = _ProdCmplncRatingText.PCPrptyRating

Annotations (16)

NameValueLevelField
EndUserText.label Stability in Water view
AbapCatalog.sqlViewName CPCECTXSTBWTP view
AbapCatalog.compiler.compareFilter true view
AbapCatalog.preserveKey true view
AccessControl.authorizationCheck #MANDATORY view
AccessControl.personalData.blocking #NOT_REQUIRED view
Metadata.allowExtensions true view
ClientHandling.algorithm #SESSION_VARIABLE view
VDM.viewType #CONSUMPTION view
ObjectModel.transactionalProcessingDelegated true view
ObjectModel.createEnabled true view
ObjectModel.updateEnabled true view
ObjectModel.deleteEnabled true view
ObjectModel.usageType.dataClass #MIXED view
ObjectModel.usageType.sizeCategory #L view
ObjectModel.usageType.serviceQuality #C view

Fields (16)

KeyFieldSource TableSource FieldDescription
UpperLimitofpHValuePCEctxPHScaleUprVal
PCEctxStbltyWaterTempQtyUoMTxt
PCEctxHalfLifeUoMTxt
PCEctxMethodPhrsTxt
NotePCEctxNoteText
EHFND_RATINGPCEctxRating
PCPrptyRatingText
PCEctxAddlStatementPhrsTxt
PCEctxAssmtPhrsTxt
CreateatdatetimeCreationUTCDateTime
CreatebyuserCreatedByUser
UpdateatdatetimeLastChangeUTCDateTime
UpdatebyuserLastChangedByUser
SubstanceUUID
_PCEctxProperty _PCEctxProperty
_UnitOfMeasureTemperature _UnitOfMeasureTemperature

Derived SQL interpretation, reconstructed from the parsed view metadata (data sources, associations, and field mappings). SAP annotations are omitted and the structure is reformulated as SQL — this is a functional approximation, not the verbatim SAP source.

-- Derived SQL interpretation of CDS view C_PCEctxStbltyWaterTP.
-- Reconstructed from parsed metadata (data sources, associations, fields).
-- SAP annotations are omitted and the structure is reformulated as SQL;
-- this is a functional approximation, not the verbatim SAP source. Some join
-- conditions may be unavailable and a few CDS constructs are kept as-is.

CREATE VIEW C_PCEctxStbltyWaterTP AS
SELECT
  _UnitOfMeasureTemperature[1: Language = $session.system_language ].UnitOfMeasureName AS PCEctxStbltyWaterTempQtyUoMTxt,
  _UnitOfMeasureHalfLifeValue[1: Language = $session.system_language ].UnitOfMeasureName AS PCEctxHalfLifeUoMTxt,
  cast( '' as ehfnd_property_method ) AS PCEctxMethodPhrsTxt,
  _ProdCmplncRatingText[1: Language = $session.system_language ].PCPrptyRatingText AS PCPrptyRatingText,
  cast( '' as ehfnd_add_stmnt ) AS PCEctxAddlStatementPhrsTxt,
  cast( '' as ehfnd_assmnt ) AS PCEctxAssmtPhrsTxt
FROM I_PCEctxStbltyWaterTP
LEFT OUTER JOIN C_PCEctxPropertyTP AS _PCEctxProperty ON PCEctxPrptyUUID = _PCEctxProperty.PCEctxPrptyUUID  -- association [1..1]
LEFT OUTER JOIN I_UnitOfMeasureText AS _UnitOfMeasureTemperature ON PCEctxStbltyWaterTempQtyUoM = _UnitOfMeasureTemperature.UnitOfMeasure  -- association [0..*]
LEFT OUTER JOIN I_UnitOfMeasureText AS _UnitOfMeasureHalfLifeValue ON PCEctxHalfLifeUoM = _UnitOfMeasureHalfLifeValue.UnitOfMeasure  -- association [0..*]
LEFT OUTER JOIN I_ProdCmplncRatingText AS _ProdCmplncRatingText ON PCEctxRating = _ProdCmplncRatingText.PCPrptyRating  -- association [0..*]
;